Create a virtual device:
Name: Thermo Sensor type: Thermostat setpoint
Choose a IOT4SH01DS device for temperature sensor, in my case named it 'Nappali'.
Choose a IOT4SH01Relay device for controlling the central heating unit, in my case named 'futes'.
In the Setup-> More options -> Events
Insert this code:
--
-- Domoticz passes information to scripts through a number of global tables
--
--
--
--
-- https://www.iot4.eu/wiki
local heating_probe = 'Nappali'
local thermostat_setpoint = 'Thermo'
local heating_unit = 'futes'
local hysteresis = 0.1
commandArray = {}
-- loop through all the devices
for deviceName,deviceValue in pairs(otherdevices) do
if (deviceName== thermostat_setpoint ) then
if tonumber(deviceValue) < tonumber(otherdevices[heating_probe]-hysteresis) then
if (otherdevices[heating_unit] == "On") then
-- commandArray['SendNotification']='Heating is off'
commandArray[heating_unit]='Off'
print("Heating is Off")
end
elseif tonumber(deviceValue) > tonumber(otherdevices[heating_probe]+hysteresis) then
if (otherdevices[heating_unit] == "Off") then
commandArray[heating_unit]='On'
-- commandArray['SendNotification']='Heating is on'
print("Heating is On")
end
end
end
end
-- loop through all the variables
for variableName,variableValue in pairs(uservariables) do
end
return commandArray
The event type set to Lua and set the event to active.
If you remove the -- (lua remark) before the commandArray['SendNotification'] lines the Domoticz will be notify heating status changes.
If you want can use higher hysteresis than 0.1 celsius, just simply modify the Lua code.
When this all is ready you can simply set desired temperature with the Utility device thermo temperature.